Screw air compressor is a commonly used equipment in modern enterprise production process, which has important significance for stabilizing enterprise production. As is well known, air compressors rely on compressed air to provide power for enterprise production. Due to the high content of pollutants such as moisture, oil, and dust in compressed air, it can cause certain damage to equipment and affect its reliability. Therefore, precision filters are often equipped when using air compressors.
The main function of precision filters is to remove pollutants from compressed air so that the compressed gas can meet the production requirements of enterprises. So, what are the issues to pay attention to when installing precision filters? Below is a summary for everyone:
1. If there are multiple precision filters in the compressed air system, the filter with coarser accuracy should be installed near the gas source side, and the filter with higher accuracy should be installed on the gas consumption side, that is, "coarse first, fine later".
2. When installing, pay attention to the direction and determine the inlet and outlet positions according to the direction indicated by the arrow on the housing to ensure that the inlet and outlet directions of the installed filter are determined.
3. The installation of the filter should maintain a certain height to facilitate the replacement of the filter element in the future.
4. The pipeline filter should be installed vertically on the ground, with sufficient drainage height below.
5. There should be no high-temperature heat sources or toxic or corrosive gases present near the environment where the filter is used.
6. The filter housing is a pressurized container, and during installation, it is important to avoid knocking and impact. The sealing connection should be reliable to prevent gas leakage.
7. There should be shut-off valves and bypass valves in the inlet and outlet pipelines of the filter for easy maintenance and replacement of the filter.
8. When the weather is cold, the accumulated fluid in the housing should be drained before using the filter.